  • GFI for refrigerator | Information by Electrical Professionals for . . .
    If you're under the 2017 code, the receptacle outlets that serve the countertops and receptacle outlets within 6' of a sink are required to have GFCI protection IIRC So, if the refrigerator outlet is more than 6' from the sink, GFCI protection is not required for that outlet It doesn't matter what you consider the ice maker and such to be, if their receptacle outlets are within the scope of
  • One family dwelling RV attachment receptacle!
    Aren't the GFCI requirements for 15A 20A, 120V? The RV is a 30A receptacle I'm not speaking of the new requirements for 240V, 50A circuits Since this is a dwelling 210 8 (F) applies 210 8 (F) Outdoor Outlets
  • RV Outlet | Information by Electrical Professionals for Electrical . . .
    We installed 50 amp 4 wire outlets 120 208 volts in a RV storage area Are these required to be GFI protected? My understanding is if it is a pedestal it would not be required so if that is the case why would just an outlet be required for the same RV usage? Inspector is requiring GFCI Breakers
  • GFCI Tripping | Information by Electrical Professionals for Electrical . . .
    I have seen circuits with multiple GFCI receptacles installed incorrectly If you use a GFCI receptacle at every receptacle outlet on the the circuit, all conductors, grounded and ungrounded, should be installed on the LINE side of the devices Installing a GFCI receptacle where its fed from the load side of another GFCI receptacle will sometimes cause a nuisance trip I would check for that also
  • GFCI Distance Too Far? | Information by Electrical Professionals for . . .
    If the GFCI breaker has held fine for a year, it isnt the distance that's now causing issues eta: if you want to be completely prepared, bring a new switch, receptacle (regular and GFCI), breakers (regular and GFCI) and enough #12 or even #10 to rewire from the panel to the motor, new boxes, new in-use outdoor covers, conduit fittings
  • old gfci different then new gfci outlet why? | Information by . . .
    i noticed a gfci outlet i had a while and a new one i just bought both 20amp new one had the t shape slot old one didn't why?i don't think i've seen a appilance plug with a t shape prong
  • GFCI wiring | Information by Electrical Professionals for Electrical . . .
    Hello, working inside of a double wide mobile home wherein there is 3 GFCI outlets all on the same circuit One in each bathroom, and one mounted on the outside of the home One bathroom had GFCI outlet go bad (approximately 17 years old) and opened the circuit to the 2nd bathroom and the single
  • Receptacles Downstream of GFCIs | Information by Electrical . . .
    Especially when a non-GFCI is ~$2 and a GFCI outlet is ~$12 There are a bunch of things that can go bad with electrical stuff when ID Ten T's do electrical work