  • wire 和 cable 有啥区别? - 百度知道
    wire 和 cable 有啥区别?电缆和电线的区别与CABLE和WIRE的区别界限不完全一样,在中文中将多芯带护套的叫电缆,单芯不带护套的叫电线,绞合导体的原件叫丝;在英文中将带结缘的导体叫cable,不带绝缘的导体叫wire。
  • Shower cable 6mm or 10mm - MyBuilder
    Hi there, You can use 6mm cable for up 9 2 kW Only condition is if you have a 9 2 kW shower on a 6 mm cable it should not be more then 6 meter away from the consumer unit But 7 5 kW is ok If you have a shower more then 9 2 kW, 10mm cable must be used I normally always use 10 mm cable if the shower is 7 5 kW or more
  • Running power cables to garden shed - MyBuilder
    Electrical Running power cables to garden shed Anonymous user 23 February 2024 - 2 46 PM Hi, I want to run a permanent power cable, attached high up on a stone wall, to a garden shed about 20m from my external (ie outside wall) power socket
  • Correct electrical cable for cooker - MyBuilder
    Electrical Correct electrical cable for cooker Anonymous user 9 March 2024 - 3 26 PM Hi I have a cooker switch which has a bs6004 6mm +2 5 cable in it (written on cable) that runs from the cooker switch to the consumer unit (fuse box) need to purchase a electric cooker but unsure what the maximum watts should be used for this Think of purchasing a Rangemaster induction cooker hob cooker it
  • cable是什么意思 - 百度知道
    cable可以作为有线电视电缆,基于有线电视网而组成的网络。 它是近几年随着网络应用的扩大而发展起来的,主要使用有线电视网进行数据传输。 cable网路的特点,总带宽大,是共享型带宽,用户增多单个用户所分的带宽变小,多采用ADSL。
  • How to lay patio with electric cable - MyBuilder
    One way you could lay the cable is run it along side the patio you are laying but not under the patio so maybe leave a gap of 50m or more and bury the cable beside the patio if it requires to be covered up then you could cover it with shingle and it will be the same level as the patio and the plus side of doing that is if you ever needed to take the cable up you can without damaging your patio
  • what size cable and breaker? - MyBuilder
    As 7200w (7 2kw) divided by the voltage 230v = 31 06amps, a 6mm twin and earth cable with a BSEN60898 type B MCB will be sufficient for the circuit If the cable is being flushed into the wall and plastered over then it will also need to be RCD protected using a BSEN61008 or BSEN61009 RCD (30ma type)
  • How deep should wires be chased in to walls? - MyBuilder
    That fact that you can see the cable is evidence that the cables are inadequately mechanically protected All cables should either be contained in steel conduit or protected by 30mA RCD If these two cannot be met, then the cables should be installed at least 50mm (2") from the surface
  • Running a cable to a shed - MyBuilder
    Electrical Running a cable to a shed Anonymous user 28 February 2024 - 3 02 PM Hi, I have been reading (and learning) from the forum but I am not very knowledgeable when it comes to electricity so any advice would be greatly appreciated
  • How to extend cable in sockets - MyBuilder
    Im having internal insulation in the house and effectively this will push the wall about 70 mm out So when replacing the sockets the cables are already short How best to extend the cables? Its only just above the skirting Thought of using connector blocks but guess thats not up to regs Is there any alternative rather than replacing the cable